Modèle | SRM3-125 / 160 | SRM3-250 / 320 | SRM3-400 / 630 | SRM3-630 / 800/1250/1600 | |||||||||
Current nominal Current INM (A) | 160 | 250 | 400 | 1600 | |||||||||
Poteaux | 3.4 | 3,4 | 3,4 | 3.4 | |||||||||
Courant nominal en (a) | Srm3-125: in = 10,16,20,25,32, 40,50,63,80,100,125a | Srm3-250r: in = 100,125,140,160 180,200,225,250a | SRM3-400: IN = 225 250,315,350, 400A | SRM3-630: IN = 400 500 630A | |||||||||
Srm3-800: in = 700 800a | |||||||||||||
Srm3-160: in = 10,16,20,25,32, 40,50,63,80,100,125,140,160A | SRM3-320: IN = 280 300,315,320A | SRM3-630: IN = 400 500 630A | Srm3-1250: in = 800,900,1000,1250 | ||||||||||
SRM3-1600A: IN = 1250.1600A | |||||||||||||
Tension opérationnelle nominale UE (V) | AC400V / 415V / 500V / 660V / 690V | ||||||||||||
Tension d'isolation nominale UI (V) | 1140 | ||||||||||||
Impulsion nominale avec tension UIMP (KV) | 8 | 8 | 12 | 12 | |||||||||
Code de capacité de rupture | S | H | R | S | H | R | S | H | R | S | H | R | |
Capacité de rupture à court-circuit opérationnel ICS (KA) | AC400V / 415V | 25 | 36 | 50 | 25 | 36 | 50 | 36 | 50 | 75 | 36 | 50 | 75 |
AC500V | 20 | 20 | 20 | 20 | 20 | 20 | 25 | 36 | 50 | 25 | 36 | 50 | |
AC660V / 690V | 10 | 10 | 15 | 10 | 10 | 15 | 10 | 15 | 20 | 10 | 15 | 20 | |
Capacité de rupture à court-circuit ultime LCU (KA) | AC400V / 415V | 36 | 50 | 75 | 36 | 50 | 75 | 50 | 75 | 100 | 50 | 75 | 100 |
AC500V | 25 | 25 | 25 | 25 | 25 | 25 | 36 | 50 | 75 | 36 | 50 | 75 | |
AC660V / 690V | 15 | 15 | 20 | 15 | 15 | 20 | 15 | 20 | 25 | 15 | 20 | 25 | |
Catégorie sélective | A | ||||||||||||
Nombre de cycles d'opération | Faire monter | 6000 | 3000 | 3000 | 1500 | ||||||||
Pas PowerDon | 9000 | 7000 | 7000 | 4000 | |||||||||
Type de périphérique de voyage sur-surcure | Type thermomagnétique (type fixe) | ||||||||||||
Accessoire | Contacts auxiliaires, contacts d'alarme, unité de décalage de shunt, voyage sous-tension, mécanisme de fonctionnement manuel, mécanisme de fonctionnement électrique | ||||||||||||
Contour et Dimensions de l'installation (mm)
| Modèle | Dimensions sur les éléments | Dimensions de l'installation | |||||||||||||||
| W | W1 | W2 | L | L1 | L2 | L3 | L4 | H | H1 | H2 | H3 | H4 | A | B | B1 | φd | |
| SRM3-125 / 160 | 122 | 92 | 30 | 155 | 47.5 | 95 | 43.5 | 136 | 68.5 | 83.5 | 102 | 75.5 | 79 | 132 | 30 | 60 | 4.5 |
| SRM3-250 / 320 | 142 | 107 | 35 | 165 | 65.6 | 102 | 51 | 142 | 85 | 96 | 120 | 92 | 95.5 | 126 | 35 | 70 | 4.5 |
| SRM3-400 / 630 | 186 | 142 | 44 | 257 | 100 | 158 | 75 | 225 | 98 | 115 | 151 | 105 | 110 | 194 | 44 | 88 | 6.5 |
| SRM3-630 / 800/1250/1600 | 280 | 210 | 70 | 275.5 | 110 | 104 | 52 | 243.5 | 97.5 | 114 | 158 | 105 | 112 | 243 | 70 | 140 | 4.5 |
Conception miniaturisée: Le produit est miniaturisé en taille, qui peut répondre aux exigences personnalisées des clients pour les dimensions d'installation du produit.
Dimensions uniformes: Sous la même note de cadre de coque, les dimensions d'installation des produits avec différentes capacités de rupture (S, H, R) et différentes fonctions (type fixe thermomagnétique, type réglable thermomagnétique, type électronique) sont exactement les mêmes.
Model | SRM3RT-125/160 | SRM3RT-2501320 | SRM3RT-400/630 | SRM3RT-630/800/12501600 | |||||||||
Courant nominal de qualité INM (A) | 160 | 250 | 400 | 1600 | |||||||||
Poteaux | 3.4 | 3,4 | 3,4 | 3.4 | |||||||||
Current classé en (a) | Srm3rt-125: in = 10,16,20,25,32, 40,50,63,80,100,125a | Srm3rt-250: in = 100,125.140.160, 180,200,225,250a | Srm3rt-400 in = 225 250,315,350, 400a | SRM3RT-630: IN = 400 500 630A | |||||||||
SRM3RT-800: IN = 700 800A | |||||||||||||
Srm3rt-160: in = 10,16,20,25,32, 40,50.63.80.100.125.140.160a | SRM3RT-320: IN = 280 300,315,320A | SRM3RT-630: IN = 400 500 630A | Srm3rt-1250: in = 800,900,1000,1250 | ||||||||||
SRM3RT-1600A: IN = 1250.1600A | |||||||||||||
Tension opérationnelle nominale UE (V) | AC400V1415V / 500V / 660V / 690V | ||||||||||||
Tension d'isolation nominale UI (V) | 1140 | ||||||||||||
Impulsion nominale avec tension UIMP (KV) | 8 | 8 | 12 | 12 | |||||||||
Code de capacité de rupture | S | H | R | S | H | R | S | H | R | S | H | R | |
Capacité de rupture à court-circuit opérationnel ICS (KA) | AC400V1415V | 25 | 36 | 50 | 25 | 36 | 50 | 36 | 50 | 75 | 36 | 50 | 75 |
AC500V | 20 | 20 | 20 | 20 | 20 | 20 | 25 | 36 | 50 | 25 | 36 | 50 | |
AC660V / 690V | 10 | 10 | 15 | 10 | 10 | 15 | 10 | 15 | 20 | 10 | 15 | 20 | |
Capacité de rupture à court-circuit ultime LCU (KA) | Ac400v₁415v | 36 | 50 | 75 | 36 | 50 | 75 | 50 | 75 | 100 | 50 | 75 | 100 |
AC500V | 25 | 25 | 25 | 25 | 25 | 25 | 36 | 50 | 75 | 36 | 50 | 75 | |
AC660V / 690V | 15 | 15 | 20 | 15 | 15 | 20 | 15 | 20 | 25 | 15 | 20 | 25 | |
Catégorie sélective | A | ||||||||||||
Nombre de cycles d'opération | Faire monter | 6000 | 3000 | 3000 | 1500 | ||||||||
Pas alimenté | 9000 | 7000 | 7000 | 4000 | |||||||||
Type de périphérique de voyage sur courant | Type thermomagnétique (réglable, 0,7-1,0 pouce réglable) | ||||||||||||
Accessoire | Contacts auxiliaires, contacts d'alarme, unité de déplacement de shunt, pointe de sous-tension, mécanisme de fonctionnement manuel, mécanisme de fonctionnement électrique | ||||||||||||
Modèle | SRM3E-125/160 | SRM3E-2501320 | SRM3E-400/630 | SRM3E-630 / 800/1250/1600 | |||||||||
Current nominal Current INM (A) | 160 | 320 | 630 | 1600 | |||||||||
Poteaux | 3.4 | 3.4 | 3.4 | 3.4 | |||||||||
Courant nominal en (a) | SRM3E-125 32A: IR = 16,20,25,32A ajusté 63A: IR = 32,36,40,45,50,55,60, 63A réglable 125A: IR = 40,50,63,70,75,80,85, 90,100,125A | SRM3E-250: IR = 100,125,140,160, 180,200,225,250A | SRM3E-400: IR = 160 200,225, 250 275 300,315,350,375 400a réglable | SRM3E-630: IR = 400,420 440 460 480, 500 530 560 600 630A | |||||||||
SRM3E-800: IR = 630,640,660,680,700, 720,740 760,780,800A | |||||||||||||
SRM3E-1250: IR = 800,900,1000,1250A Réglable | |||||||||||||
SRM3E-160: IR = 63,70,75,80,85. 90,100,125,140,160A Réglable | SRM3E-320: IR = 180,200,225,250. 280 300,315,320a réglable | SRM3E-630: I = 250,280,315,350,375 400 450 500 560 630A | SRM3E-1600: IR = 1250.1600A Réglable | ||||||||||
Tension opérationnelle nominale UE (V) | AC400V / 415V / 500V / 660V / 690V | ||||||||||||
Tension d'isolation nominale UI (V) | 800 | 800 | 1140 | 1140 | |||||||||
Impulsion nominale avec tension UIMP (KV) | 8 | 8 | 12 | 12 | |||||||||
Code de capacité de rupture | S | H | R | S | H | R | S | H | R | S | H | R | |
Capacité de rupture à court-circuit opérationnel ICS (KA) | AC400V1415V | 25 | 36 | 50 | 25 | 36 | 50 | 36 | 50 | 75 | 36 | 50 | 75 |
AC500V | 20 | 20 | 20 | 20 | 20 | 20 | 25 | 36 | 50 | 25 | 36 | 50 | |
AC660V / 690V | 10 | 10 | 15 | 10 | 10 | 15 | 10 | 15 | 20 | 10 | 15 | 20 | |
Capacité de rupture à court-circuit ultime LCU (KA) | AC400V / 415V | 36 | 50 | 75 | 36 | 50 | 75 | 50 | 75 | 100 | 50 | 75 | 100 |
AC500V | 25 | 25 | 25 | 25 | 25 | 25 | 36 | 50 | 75 | 36 | 50 | 75 | |
AC660V / 690V | 15 | 15 | 20 | 15 | 15 | 20 | 15 | 20 | 25 | 15 | 20 | 25 | |
Évalué à court de temps avec ICW (KA) | 20KA, 1 | ||||||||||||
Catégorie sélective | B | ||||||||||||
Nombre de cycles d'opération | Faire monter | 3000 | 3000 | 2000 | 1500 | ||||||||
Pas alimenté | 7000 | 7000 | 4000 | 4000 | |||||||||
Type de périphérique de voyage sur courant | Type électronique | ||||||||||||
Accessoire | Contacts auxiliaires, contacts d'alarme, unité de décalage de shunt, voyage sous-tension, mécanisme de fonctionnement manuel, mécanisme de fonctionnement électrique | ||||||||||||
Modèle | SRM3-125 / 160 | SRM3-250 / 320 | SRM3-400 / 630 | SRM3-630 / 800/1250/1600 | |||||||||
Current nominal Current INM (A) | 160 | 250 | 400 | 1600 | |||||||||
Poteaux | 3.4 | 3,4 | 3,4 | 3.4 | |||||||||
Courant nominal en (a) | Srm3-125: in = 10,16,20,25,32, 40,50,63,80,100,125a | Srm3-250r: in = 100,125,140,160 180,200,225,250a | SRM3-400: IN = 225 250,315,350, 400A | SRM3-630: IN = 400 500 630A | |||||||||
Srm3-800: in = 700 800a | |||||||||||||
Srm3-160: in = 10,16,20,25,32, 40,50,63,80,100,125,140,160A | SRM3-320: IN = 280 300,315,320A | SRM3-630: IN = 400 500 630A | Srm3-1250: in = 800,900,1000,1250 | ||||||||||
SRM3-1600A: IN = 1250.1600A | |||||||||||||
Tension opérationnelle nominale UE (V) | AC400V / 415V / 500V / 660V / 690V | ||||||||||||
Tension d'isolation nominale UI (V) | 1140 | ||||||||||||
Impulsion nominale avec tension UIMP (KV) | 8 | 8 | 12 | 12 | |||||||||
Code de capacité de rupture | S | H | R | S | H | R | S | H | R | S | H | R | |
Capacité de rupture à court-circuit opérationnel ICS (KA) | AC400V / 415V | 25 | 36 | 50 | 25 | 36 | 50 | 36 | 50 | 75 | 36 | 50 | 75 |
AC500V | 20 | 20 | 20 | 20 | 20 | 20 | 25 | 36 | 50 | 25 | 36 | 50 | |
AC660V / 690V | 10 | 10 | 15 | 10 | 10 | 15 | 10 | 15 | 20 | 10 | 15 | 20 | |
Capacité de rupture à court-circuit ultime LCU (KA) | AC400V / 415V | 36 | 50 | 75 | 36 | 50 | 75 | 50 | 75 | 100 | 50 | 75 | 100 |
AC500V | 25 | 25 | 25 | 25 | 25 | 25 | 36 | 50 | 75 | 36 | 50 | 75 | |
AC660V / 690V | 15 | 15 | 20 | 15 | 15 | 20 | 15 | 20 | 25 | 15 | 20 | 25 | |
Catégorie sélective | A | ||||||||||||
Nombre de cycles d'opération | Faire monter | 6000 | 3000 | 3000 | 1500 | ||||||||
Pas PowerDon | 9000 | 7000 | 7000 | 4000 | |||||||||
Type de périphérique de voyage sur-surcure | Type thermomagnétique (type fixe) | ||||||||||||
Accessoire | Contacts auxiliaires, contacts d'alarme, unité de décalage de shunt, voyage sous-tension, mécanisme de fonctionnement manuel, mécanisme de fonctionnement électrique | ||||||||||||
Contour et Dimensions de l'installation (mm)
| Modèle | Dimensions sur les éléments | Dimensions de l'installation | |||||||||||||||
| W | W1 | W2 | L | L1 | L2 | L3 | L4 | H | H1 | H2 | H3 | H4 | A | B | B1 | φd | |
| SRM3-125 / 160 | 122 | 92 | 30 | 155 | 47.5 | 95 | 43.5 | 136 | 68.5 | 83.5 | 102 | 75.5 | 79 | 132 | 30 | 60 | 4.5 |
| SRM3-250 / 320 | 142 | 107 | 35 | 165 | 65.6 | 102 | 51 | 142 | 85 | 96 | 120 | 92 | 95.5 | 126 | 35 | 70 | 4.5 |
| SRM3-400 / 630 | 186 | 142 | 44 | 257 | 100 | 158 | 75 | 225 | 98 | 115 | 151 | 105 | 110 | 194 | 44 | 88 | 6.5 |
| SRM3-630 / 800/1250/1600 | 280 | 210 | 70 | 275.5 | 110 | 104 | 52 | 243.5 | 97.5 | 114 | 158 | 105 | 112 | 243 | 70 | 140 | 4.5 |
Conception miniaturisée: Le produit est miniaturisé en taille, qui peut répondre aux exigences personnalisées des clients pour les dimensions d'installation du produit.
Dimensions uniformes: Sous la même note de cadre de coque, les dimensions d'installation des produits avec différentes capacités de rupture (S, H, R) et différentes fonctions (type fixe thermomagnétique, type réglable thermomagnétique, type électronique) sont exactement les mêmes.
Model | SRM3RT-125/160 | SRM3RT-2501320 | SRM3RT-400/630 | SRM3RT-630/800/12501600 | |||||||||
Courant nominal de qualité INM (A) | 160 | 250 | 400 | 1600 | |||||||||
Poteaux | 3.4 | 3,4 | 3,4 | 3.4 | |||||||||
Current classé en (a) | Srm3rt-125: in = 10,16,20,25,32, 40,50,63,80,100,125a | Srm3rt-250: in = 100,125.140.160, 180,200,225,250a | Srm3rt-400 in = 225 250,315,350, 400a | SRM3RT-630: IN = 400 500 630A | |||||||||
SRM3RT-800: IN = 700 800A | |||||||||||||
Srm3rt-160: in = 10,16,20,25,32, 40,50.63.80.100.125.140.160a | SRM3RT-320: IN = 280 300,315,320A | SRM3RT-630: IN = 400 500 630A | Srm3rt-1250: in = 800,900,1000,1250 | ||||||||||
SRM3RT-1600A: IN = 1250.1600A | |||||||||||||
Tension opérationnelle nominale UE (V) | AC400V1415V / 500V / 660V / 690V | ||||||||||||
Tension d'isolation nominale UI (V) | 1140 | ||||||||||||
Impulsion nominale avec tension UIMP (KV) | 8 | 8 | 12 | 12 | |||||||||
Code de capacité de rupture | S | H | R | S | H | R | S | H | R | S | H | R | |
Capacité de rupture à court-circuit opérationnel ICS (KA) | AC400V1415V | 25 | 36 | 50 | 25 | 36 | 50 | 36 | 50 | 75 | 36 | 50 | 75 |
AC500V | 20 | 20 | 20 | 20 | 20 | 20 | 25 | 36 | 50 | 25 | 36 | 50 | |
AC660V / 690V | 10 | 10 | 15 | 10 | 10 | 15 | 10 | 15 | 20 | 10 | 15 | 20 | |
Capacité de rupture à court-circuit ultime LCU (KA) | Ac400v₁415v | 36 | 50 | 75 | 36 | 50 | 75 | 50 | 75 | 100 | 50 | 75 | 100 |
AC500V | 25 | 25 | 25 | 25 | 25 | 25 | 36 | 50 | 75 | 36 | 50 | 75 | |
AC660V / 690V | 15 | 15 | 20 | 15 | 15 | 20 | 15 | 20 | 25 | 15 | 20 | 25 | |
Catégorie sélective | A | ||||||||||||
Nombre de cycles d'opération | Faire monter | 6000 | 3000 | 3000 | 1500 | ||||||||
Pas alimenté | 9000 | 7000 | 7000 | 4000 | |||||||||
Type de périphérique de voyage sur courant | Type thermomagnétique (réglable, 0,7-1,0 pouce réglable) | ||||||||||||
Accessoire | Contacts auxiliaires, contacts d'alarme, unité de déplacement de shunt, pointe de sous-tension, mécanisme de fonctionnement manuel, mécanisme de fonctionnement électrique | ||||||||||||
Modèle | SRM3E-125/160 | SRM3E-2501320 | SRM3E-400/630 | SRM3E-630 / 800/1250/1600 | |||||||||
Current nominal Current INM (A) | 160 | 320 | 630 | 1600 | |||||||||
Poteaux | 3.4 | 3.4 | 3.4 | 3.4 | |||||||||
Courant nominal en (a) | SRM3E-125 32A: IR = 16,20,25,32A ajusté 63A: IR = 32,36,40,45,50,55,60, 63A réglable 125A: IR = 40,50,63,70,75,80,85, 90,100,125A | SRM3E-250: IR = 100,125,140,160, 180,200,225,250A | SRM3E-400: IR = 160 200,225, 250 275 300,315,350,375 400a réglable | SRM3E-630: IR = 400,420 440 460 480, 500 530 560 600 630A | |||||||||
SRM3E-800: IR = 630,640,660,680,700, 720,740 760,780,800A | |||||||||||||
SRM3E-1250: IR = 800,900,1000,1250A Réglable | |||||||||||||
SRM3E-160: IR = 63,70,75,80,85. 90,100,125,140,160A Réglable | SRM3E-320: IR = 180,200,225,250. 280 300,315,320a réglable | SRM3E-630: I = 250,280,315,350,375 400 450 500 560 630A | SRM3E-1600: IR = 1250.1600A Réglable | ||||||||||
Tension opérationnelle nominale UE (V) | AC400V / 415V / 500V / 660V / 690V | ||||||||||||
Tension d'isolation nominale UI (V) | 800 | 800 | 1140 | 1140 | |||||||||
Impulsion nominale avec tension UIMP (KV) | 8 | 8 | 12 | 12 | |||||||||
Code de capacité de rupture | S | H | R | S | H | R | S | H | R | S | H | R | |
Capacité de rupture à court-circuit opérationnel ICS (KA) | AC400V1415V | 25 | 36 | 50 | 25 | 36 | 50 | 36 | 50 | 75 | 36 | 50 | 75 |
AC500V | 20 | 20 | 20 | 20 | 20 | 20 | 25 | 36 | 50 | 25 | 36 | 50 | |
AC660V / 690V | 10 | 10 | 15 | 10 | 10 | 15 | 10 | 15 | 20 | 10 | 15 | 20 | |
Capacité de rupture à court-circuit ultime LCU (KA) | AC400V / 415V | 36 | 50 | 75 | 36 | 50 | 75 | 50 | 75 | 100 | 50 | 75 | 100 |
AC500V | 25 | 25 | 25 | 25 | 25 | 25 | 36 | 50 | 75 | 36 | 50 | 75 | |
AC660V / 690V | 15 | 15 | 20 | 15 | 15 | 20 | 15 | 20 | 25 | 15 | 20 | 25 | |
Évalué à court de temps avec ICW (KA) | 20KA, 1 | ||||||||||||
Catégorie sélective | B | ||||||||||||
Nombre de cycles d'opération | Faire monter | 3000 | 3000 | 2000 | 1500 | ||||||||
Pas alimenté | 7000 | 7000 | 4000 | 4000 | |||||||||
Type de périphérique de voyage sur courant | Type électronique | ||||||||||||